Smoke / CO / Gas Detectors
Expected delivery 3 to 7 business days (exceptions applied)
Macurco
Panneau de commande Macurco, 120 V, 12 entrées de capteur analogique, 3 relais (DVP-120M)
Panneau de commande Macurco, 120 V, 12 entrées de capteur analogique, 3 relais (DVP-120M)
Prix habituel
$2,639.99 CAD
Prix habituel
$2,956.99 CAD
Prix promotionnel
$2,639.99 CAD
Prix unitaire
/
par
Frais d'expédition calculés à l'étape de paiement.
Panneau de commande Macurco, 120 V, 12 entrées de capteur analogique, 3 relais (DVP-120M)
VPN : DVP-120M SKU : AT651969 CUP : 783748833207
Impossible de charger la disponibilité du service de retrait
Remise sur volume disponible - Demandez un devis.
Afficher tous les détails

Recently Viewed
Panneau de commande Macurco, 120 V, 12 entrées de capteur analogique, 3 relais (DVP-120M)
Résumé des informations sur le produit
À propos du produit
This control panel from Macurco is compatible with 6-series detectors in commercial facilities such as parking garages, large warehouses and vehicle maintenance facilities. By activating fans, it can help maintain acceptable levels of carbon monoxide and other gasses.
The DVP-120 can work with up to 87 digital and 12 analog Macurco 6 series gas detectors. It has three relay outputs to control fans, two siren/strobe driver outputs. Up to three ventilation zones can be defined and each zone can be controlled by transducer signals or time of day. Each zone responds to gas levels at one or more sensors, with configurable rising and falling concentrations for each gas type. Each zone can be controlled by the time of day.
The DVP-120 can work with up to 87 digital and 12 analog Macurco 6 series gas detectors. It has three relay outputs to control fans, two siren/strobe driver outputs. Up to three ventilation zones can be defined and each zone can be controlled by transducer signals or time of day. Each zone responds to gas levels at one or more sensors, with configurable rising and falling concentrations for each gas type. Each zone can be controlled by the time of day.
Macurco DVP-120M Control Panel Features:
- Compatible with Macurco 6-Series
- 87 digital sensor connections (RS-485) + 12 analog (4-20mA) sensor connections
- Three 10A SPDT fan / alarm relays
- Two 24VDC drivers for Horn / Strobe
- External keypad for user selection of the transducer/alarm display and setting the configuration
- LED Indicators for Power, ALARM/warning, hush, Relay 1, Relay 2 & Relay 3
- Settings are customizable, default is per OSHA
- Operating temperature: 32°F to 104°F (0°C to 40°C)
- Dimensions: 10.5” x 12.5” x 2.” (10.5 X 37.75 X 5.08 cm)
- 2-year limited warranty
Spécifications techniques
This control panel from Macurco is compatible with 6-series detectors in commercial facilities such as parking garages, large warehouses and vehicle maintenance facilities. By activating fans, it can help maintain acceptable levels of carbon monoxide and other gasses.
The DVP-120 can work with up to 87 digital and 12 analog Macurco 6 series gas detectors. It has three relay outputs to control fans, two siren/strobe driver outputs. Up to three ventilation zones can be defined and each zone can be controlled by transducer signals or time of day. Each zone responds to gas levels at one or more sensors, with configurable rising and falling concentrations for each gas type. Each zone can be controlled by the time of day.
The DVP-120 can work with up to 87 digital and 12 analog Macurco 6 series gas detectors. It has three relay outputs to control fans, two siren/strobe driver outputs. Up to three ventilation zones can be defined and each zone can be controlled by transducer signals or time of day. Each zone responds to gas levels at one or more sensors, with configurable rising and falling concentrations for each gas type. Each zone can be controlled by the time of day.
Macurco DVP-120M Control Panel Features:
- Compatible with Macurco 6-Series
- 87 digital sensor connections (RS-485) + 12 analog (4-20mA) sensor connections
- Three 10A SPDT fan / alarm relays
- Two 24VDC drivers for Horn / Strobe
- External keypad for user selection of the transducer/alarm display and setting the configuration
- LED Indicators for Power, ALARM/warning, hush, Relay 1, Relay 2 & Relay 3
- Settings are customizable, default is per OSHA
- Operating temperature: 32°F to 104°F (0°C to 40°C)
- Dimensions: 10.5” x 12.5” x 2.” (10.5 X 37.75 X 5.08 cm)
- 2-year limited warranty
Comparaison de produits
Garantie du produit
Garantie standard du fabricant, le cas échéant
Politique de retour
Garantie de prix
!00% nous sommes toujours en dessous du prix du marché.
Explorez les collections de marque
Nos services
1
/
de
5
Devenez notre partenaire
Éthique et intégrité des affaires élevées
Cohérence et performance ciblée
Vision partagée et succès partagé
Haute confidentialité et sécurité
-
Voir plusConcevoir et construire des espaces de travail, des salles de conférence et des salles de réunion
-
Voir plusService informatique géré, services d'assistance, serveurs et réseaux
-
Voir plusÉvaluation, acquisition et personnalisation des appareils de nouvelle génération
-
Voir plusContinuité des activités, sécurité, sauvegarde et reprise après sinistre
-
Voir plusStructure du cloud, migration, optimisation et sécurité
-
Voir plusNumérisation, conservation des données, automatisation, applications de développement