Unité de distribution d'alimentation Eaton G4 42 prises - Mesure - Entrée universelle - 24 x IEC 60320 C

Unité de distribution d'alimentation Eaton G4 42 prises - Mesure - Entrée universelle - 24 x IEC 60320 C

Prix habituel $2,831.95 CAD
Prix habituel $3,171.79 CAD Prix promotionnel $2,831.95 CAD
-10% OFF Épuisé
Frais d'expédition calculés à l'étape de paiement.
Unité de distribution d'alimentation Eaton G4 42 prises - Mesure - Entrée universelle - 24 x IEC 60320 C13, 18 x IEC 60320 C39 - Réseau (RJ-45) - 0U - Vertical - Montable en rack - Vertical

VPN : EVMIGU23X SKU : RSC662417 UPC :

  • Alimentation électrique installée sur des racks d'ordinateurs et d'équipements réseau dans un centre de données
  • Le PDU distribue l'alimentation CA à plusieurs serveurs et équilibre la charge sur les serveurs
  • Surveillez efficacement le niveau de charge avec le compteur PDU

Bloc de texte

Remise sur volume disponible - Demandez un devis.

Afficher tous les détails

Recently Viewed

Unité de distribution d'alimentation Eaton G4 42 prises - Mesure - Entrée universelle - 24 x IEC 60320 C

Résumé des informations sur le produit

Unité de distribution d'alimentation Eaton G4 42 prises - Mesure - Entrée universelle - 24 x IEC 60320 C

À propos du produit

17 Removable Power Cables with 15 Different Plugs Support Universal Input

This G4 universal input PDU (UPDU) is designed to meet your most diverse rack-power needs. With 42 outlets, the EVMIGU23X accommodates power needs ranging from 5kVA single-phase to 23kVA three-phase. Pair the UPDU with any one of 17 removable power cables with 15 different plug options (all sold separately). This UPDU alleviates the cost and complexity of mixing and matching different PDUs for different installations. It also ensures you won't outgrow your PDU as your power needs evolve.

Market-Leading Cybersecurity Ensures Your Data Is Kept Safe

Chain-of-trust encryption, a user-configurable firewall and secure firmware boot capability prevent the EVMIGU23X UPDU from being a cyberattack vulnerability point on a network. The embedded, hot-swappable Gigabit Network Module (GNM) offers enhanced management and cybersecurity, including zero-trust architecture and zero-touch provisioning. The EVMIGU23X-E is compatible with select Eaton Brightlayer Data Centers suite software solutions that enable extensive automation and remote management to shorten response times to power issues and ensure timely updates for stronger cybersecurity.

Remote Management Saves Time and Money

Remote PDU management reduces or eliminates costly on-site visits by sending automated alerts about power issues and remotely rebooting a PDU or individual outlets. This improves response time and frees up resources for other tasks, which is especially critical in edge of network and distributed IT installations.

42 Outlets Give You Plenty of Power Options

The EVMIGU23X features 24 C13 outlets, which accept C14 connectors, and 18 high-retention C39 combo outlets, which accept both C14 and C20 connectors, adding flexibility to deployments and reducing the quantity of PDUs you will need to purchase and install. The outlets are evenly distributed into six color-coded load banks, each with its own circuit breaker, to improve load balancing and organize connections in a crowded rack.

Convenient Box-to-Rack Installation

This G4 UPDU features toolless mounting buttons that allow front- or side-facing rack installation, depending on your rack's layout and your power needs. Choose from a collection of 17 power cables and 15 plug options (all power cables sold separately). Low-profile circuit breakers are flush with the lightweight aluminum chassis, and its narrow two-inch width saves space within the rack for revenue-generating equipment. You can cascade up to 40 EVMIGU23X models with each model maintaining its own individual IP address from a single network connection point.

Meets Global Approval

This G4 UPDU meets industry standards all over the world, making it compatible in a broad range of IT facilities, not just physically, but also from a regulatory perspective.

  • Electric power fitted to racks of computers and networking equipment within a data center
  • PDU distributes AC power to multiple servers and balances the load on the servers
  • Monitor load level efficiently with PDU meter

Spécifications techniques

Interfaces/Ports
Network (RJ-45)Yes
Miscellaneous
Certifications & Standards
  • FCC Part 15 Class A
  • CAN ICES-003 Class A
  • UL 62368-1
  • cTUVus
Environmental Conditions
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Power Description
Input Current55 A
Power Rating (Watt)23 kW
Technical Information
Plug/Connector TypeUniversal Input
Receptacle TypeIEC 60320 C39
IEC 60320 C13
PDU TypeMetered
Receptacle Detail24 x IEC 60320 C13
18 x IEC 60320 C39
General Information
Product TypePDU
Manufacturer Part NumberEVMIGU23X
Manufacturer Website Addresshttp://www.eaton.com/EatonCom/Markets/NorthAmerica
ManufacturerEaton Corporation
Product NameG4 42-Outlets PDU
Product SeriesG4
Brand NameEaton
Physical Characteristics
Weight (Approximate)9.70 lb (4399.85 g)
Form FactorVertical
Mount TypeRack-mountable
Rack Height0U
Height72" (1828.80 mm)
Width2.56" (65.02 mm)
Depth2.05" (52.07 mm)
Mounting OrientationVertical

Comparaison de produits

Garantie du produit

Garantie standard du fabricant, le cas échéant

Politique de retour

Garantie de prix

!00% nous sommes toujours en dessous du prix du marché.

Explorez les collections de marque

Nos services

1 de 5
  • Colonne

    Concevoir et construire des espaces de travail, des salles de conférence et des salles de réunion
    Voir plus 
  • Colonne

    Service informatique géré, services d'assistance, serveurs et réseaux
    Voir plus 
  • Colonne

    Évaluation, acquisition et personnalisation des appareils de nouvelle génération
    Voir plus 
  • Colonne

    Continuité des activités, sécurité, sauvegarde et reprise après sinistre
    Voir plus 
  • Colonne

    Structure du cloud, migration, optimisation et sécurité
    Voir plus 
  • Colonne

    Numérisation, conservation des données, automatisation, applications de développement
    Voir plus 

Contactez-nous