Partager
Electrical Products
Expected delivery 3 to 7 business days (exceptions applied)
Dataprobe
Dataprobe iBoot-PDU8A-2N20, 2 unités de distribution d'alimentation commutées NEMA, 8 prises, 20 A (IBOOT-PDU8A-2N20)
Dataprobe iBoot-PDU8A-2N20, 2 unités de distribution d'alimentation commutées NEMA, 8 prises, 20 A (IBOOT-PDU8A-2N20)
Dataprobe iBoot-PDU8A-2N20, 2 unités de distribution d'alimentation commutées NEMA, 8 prises, 20 A (IBOOT-PDU8A-2N20)
VPN : IBOOT-PDU8A-2N20 SKU : AT709512 UPC : 700220864597
Bloc de texte
Impossible de charger la disponibilité du service de retrait
Remise sur volume disponible - Demandez un devis.
Afficher tous les détails

Recently Viewed
Dataprobe iBoot-PDU8A-2N20, 2 unités de distribution d'alimentation commutées NEMA, 8 prises, 20 A (IBOOT-PDU8A-2N20)
Résumé des informations sur le produit

À propos du produit
Dataprobe iBoot-PDU8A-2N20, 2 NEMA, Switched PDU 8 Outlet 20A Overview
Dataprobe iBoot-PDU8A-2N20 is a Power Distribution Unit with no fan & clear, easy-to-use web interface. This rack-mounted PDU makes it easy to manage A/C power from any location. This is a switched and managed PDU, each outlet is independently controlled.
The web page presents a clear status indication of each outlet, current draw across all inputs, and the AutoPing monitoring if implemented. Multiple PDUs can be managed from a single web page.
Each outlet on this PDU can be individually selected, or multiple outlets can be simultaneously operated. User-selectable cycle timer allows a single command reboot. Delay timer limits inrush current by staggering power up when multiple devices are simultaneously controlled.
Monitor critical parameters and take corrective action immediately. Build complex notification and reporting for environmental, power, and network faults. Set trigger points and create sequences of responses to keep your network up and running.
Boot Cloud Service (iBCS) allows customers with this PDU to access and control multiple units in multiple locations from a single portal with a single sign-on.
iBCS will not only make using the PDU easier, by consolidating all units into one sign-on and interface, but it will also enhance the number of situations where a switched PDU can be deployed.
Customers with Dynamic IP addressing to always be able to access their iBoot from any location. Service providers manage multiple customers accounts with diverse security configurations. Customers that do not allow inbound connections to access their iboots.
Dataprobe iBoot-PDU8A-2N20, 2 NEMA Features:
- Independently Controllable Outlets
- Web Browser Control
- Integrated 1Gig Ethernet Switch
- Multiple Users
- Multiple iBoot-PDU Cluster Configuration
- Real-Time Event Control
- Network Management
- Telnet/Serial CLI Control
- Grouping of Outlets for Simultaneous Management
- Automation
- Landline Modem Option
Dataprobe iBoot-PDU8A-2N20, 2 NEMA Specifications:
- Physical
- Height: 1U 1.75"" (4.5cm)
- Width: 11"" (27.94cm)
- Depth: 6"" (15.25cm)
- Weight: 4.5Lbs (2kg)
- Temperature
- Operating: 32° to 149°F (0° to 65°C)
- Storage: 14° to 185°F (-10° to 85°C)
- Relative Humidity: 0 to 95% Non-Condensing
- Altitude: 2000m Operating
- Network
- Single or Dual (S Models) 1G Ethernet
- Web, Telnet, SNMP, SMTP
- Port Assignable for Web and Telnet.
- SSL Security on Web control
- Temperature Module Option
- USB Dual Temperature Sensors. Sensor 2 on 1m cable.
- Switched Outlet
- 4 or 8 IEC 320 C13 Receptacle
- 10 Amps Max per Receptacle
- -C10 Models: 15 Amps Max per Line cord
- -C20 Models: 20 Amps Max per Line cord
- AC Input
- 100-240 VAC VAC
- 10 AMP Models: IEC320 C14 Receptacle
- 20 AMP Models: IEC320 C20 Receptacle
- USB Ports
- 4x USB A ports for accessories, modem, temperature probe, etc.
- 1x USB B port for serial port and external battery
- Landline Modem Option
- 56Kbps V.92 Global Compliance, Data or Tone Dial (DTMF) control
- Compliance
- UL/cUL Listed 60950-1, 2nd Edition 2014-10-14 (US)
- CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Canada)CE Marked
- RoHS2 Directive 2011/65/EU Compliant / WEEE Compliant
- ANSI C63.4:2014 & 47 CFR Part 15, Subpart B, Class B
- ICES-003:2016 Issue 6, Class BFCC Part 15 Class B
Spécifications techniques
Dataprobe iBoot-PDU8A-2N20, 2 NEMA, Switched PDU 8 Outlet 20A Overview
Dataprobe iBoot-PDU8A-2N20 is a Power Distribution Unit with no fan & clear, easy-to-use web interface. This rack-mounted PDU makes it easy to manage A/C power from any location. This is a switched and managed PDU, each outlet is independently controlled.
The web page presents a clear status indication of each outlet, current draw across all inputs, and the AutoPing monitoring if implemented. Multiple PDUs can be managed from a single web page.
Each outlet on this PDU can be individually selected, or multiple outlets can be simultaneously operated. User-selectable cycle timer allows a single command reboot. Delay timer limits inrush current by staggering power up when multiple devices are simultaneously controlled.
Monitor critical parameters and take corrective action immediately. Build complex notification and reporting for environmental, power, and network faults. Set trigger points and create sequences of responses to keep your network up and running.
Boot Cloud Service (iBCS) allows customers with this PDU to access and control multiple units in multiple locations from a single portal with a single sign-on.
iBCS will not only make using the PDU easier, by consolidating all units into one sign-on and interface, but it will also enhance the number of situations where a switched PDU can be deployed.
Customers with Dynamic IP addressing to always be able to access their iBoot from any location. Service providers manage multiple customers accounts with diverse security configurations. Customers that do not allow inbound connections to access their iboots.
Dataprobe iBoot-PDU8A-2N20, 2 NEMA Features:
- Independently Controllable Outlets
- Web Browser Control
- Integrated 1Gig Ethernet Switch
- Multiple Users
- Multiple iBoot-PDU Cluster Configuration
- Real-Time Event Control
- Network Management
- Telnet/Serial CLI Control
- Grouping of Outlets for Simultaneous Management
- Automation
- Landline Modem Option
Dataprobe iBoot-PDU8A-2N20, 2 NEMA Specifications:
- Physical
- Height: 1U 1.75"" (4.5cm)
- Width: 11"" (27.94cm)
- Depth: 6"" (15.25cm)
- Weight: 4.5Lbs (2kg)
- Temperature
- Operating: 32° to 149°F (0° to 65°C)
- Storage: 14° to 185°F (-10° to 85°C)
- Relative Humidity: 0 to 95% Non-Condensing
- Altitude: 2000m Operating
- Network
- Single or Dual (S Models) 1G Ethernet
- Web, Telnet, SNMP, SMTP
- Port Assignable for Web and Telnet.
- SSL Security on Web control
- Temperature Module Option
- USB Dual Temperature Sensors. Sensor 2 on 1m cable.
- Switched Outlet
- 4 or 8 IEC 320 C13 Receptacle
- 10 Amps Max per Receptacle
- -C10 Models: 15 Amps Max per Line cord
- -C20 Models: 20 Amps Max per Line cord
- AC Input
- 100-240 VAC VAC
- 10 AMP Models: IEC320 C14 Receptacle
- 20 AMP Models: IEC320 C20 Receptacle
- USB Ports
- 4x USB A ports for accessories, modem, temperature probe, etc.
- 1x USB B port for serial port and external battery
- Landline Modem Option
- 56Kbps V.92 Global Compliance, Data or Tone Dial (DTMF) control
- Compliance
- UL/cUL Listed 60950-1, 2nd Edition 2014-10-14 (US)
- CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Canada)CE Marked
- RoHS2 Directive 2011/65/EU Compliant / WEEE Compliant
- ANSI C63.4:2014 & 47 CFR Part 15, Subpart B, Class B
- ICES-003:2016 Issue 6, Class BFCC Part 15 Class B
Comparaison de produits
Garantie du produit
Garantie standard du fabricant, le cas échéant
Politique de retour
Garantie de prix
!00% nous sommes toujours en dessous du prix du marché.
Explorez les collections de marque
Nos services

Devenez notre partenaire
Racontez l'histoire de votre marque à travers des images

Éthique et intégrité des affaires élevées
Racontez l'histoire de votre marque à travers des images

Cohérence et performance ciblée
Racontez l'histoire de votre marque à travers des images

Vision partagée et succès partagé
Racontez l'histoire de votre marque à travers des images

Haute confidentialité et sécurité
Racontez l'histoire de votre marque à travers des images