1
/
de
6
Partager
Rack Equipments
Expected delivery 3 to 7 business days (exceptions applied)
Tripp Lite
Unité de distribution d'alimentation Tripp Lite by Eaton PDU3EVN6L2120 45 prises - Surveillance - NEMA L21
Unité de distribution d'alimentation Tripp Lite by Eaton PDU3EVN6L2120 45 prises - Surveillance - NEMA L21
Prix habituel
$1,321.75 CAD
Prix habituel
$1,480.36 CAD
Prix promotionnel
$1,321.75 CAD
Prix unitaire
/
par
Frais d'expédition calculés à l'étape de paiement.
Unité de distribution d'alimentation Tripp Lite by Eaton PDU3EVN6L2120 45 prises - Surveillée - NEMA L21-20P - 36 x IEC 60320 C13, 6 x IEC 60320 C19, 3 x NEMA 5-15/20R - 230 V CA - Réseau (RJ-45) - 0 U - Verticale - Montable en rack VPN : PDU3EVN6L2120 SKU : RSC212105 UPC : 37332206787
- Un appareil équipé de sorties multiples pour la distribution de l'énergie électrique
- Le PDU améliore l'efficacité, la disponibilité et la croissance des centres de données
- Avec un PDU surveillé, vous pouvez facilement surveiller à distance la tension monophasée ou triphasée
Bloc de texte
Impossible de charger la disponibilité du service de retrait
Remise sur volume disponible - Demandez un devis.
Afficher tous les détails





Recently Viewed
Unité de distribution d'alimentation Tripp Lite by Eaton PDU3EVN6L2120 45 prises - Surveillance - NEMA L21
Résumé des informations sur le produit

À propos du produit
5.8kW 3-phase PDU with multifunction touchscreen LCD distributes and monitors AC power in an IT or industrial environment.
Features
3-Phase 0U PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.
45 Outlets Dispense AC Power to Connected Equipment
During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks-three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Features
3-Phase 0U PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.
45 Outlets Dispense AC Power to Connected Equipment
During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks-three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
- A device fitted with multiple outputs for the distribution of electric power
- PDU improves efficiency, uptime and growth of data centers
- With monitored PDU, you can remotely monitor single-or three-phase voltage easily
- Before critical input source become overloaded always be warned with monitored PDUs
Spécifications techniques
Interfaces/Ports | |
Network (RJ-45) | Yes |
Management | |
Management |
|
Miscellaneous | |
Package Contents |
|
Country of Origin | Taiwan |
Environmentally Friendly | Yes |
TAA Compliant | Yes |
Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Power Description | |
Input Voltage | 230 V AC |
Output Voltage | 120 V AC |
208 V AC | |
Input Current | 16 A |
Power Rating (Watt) | 5.80 kW |
General Information | |
Product Type | PDU |
Manufacturer Part Number | PDU3EVN6L2120 |
Manufacturer Website Address | http://www.eaton.com/EatonCom/Markets/NorthAmerica |
Manufacturer | Eaton Corporation |
Product Model | PDU3EVN6L2120 |
Product Name | PDU3EVN6L2120 45-Outlet PDU |
Brand Name | Tripp Lite by Eaton |
Physical Characteristics | |
Weight (Approximate) | 13.50 lb (6123.50 g) |
Mount Type | Rack-mountable |
Rack Height | 0U |
Height | 70" (1778 mm) |
Width | 2.17" (55.12 mm) |
Depth | 2.52" (64.01 mm) |
Mounting Orientation | Vertical |
Technical Information | |
Plug/Connector Type | NEMA L21-20P |
Phase | Three Phase |
Receptacle Type | NEMA 5-15/20R |
IEC 60320 C19 | |
IEC 60320 C13 | |
PDU Type | Monitored |
Receptacle Detail | 36 x IEC 60320 C13 |
3 x NEMA 5-15/20R | |
6 x IEC 60320 C19 | |
Plug/Connector Detail | 1 x NEMA L21-20P |
Comparaison de produits
Garantie du produit
Garantie standard du fabricant, le cas échéant
Politique de retour
Garantie de prix
!00% nous sommes toujours en dessous du prix du marché.
Explorez les collections de marque
Nos services
1
/
de
5

Devenez notre partenaire
Racontez l'histoire de votre marque à travers des images

Éthique et intégrité des affaires élevées
Racontez l'histoire de votre marque à travers des images

Cohérence et performance ciblée
Racontez l'histoire de votre marque à travers des images

Vision partagée et succès partagé
Racontez l'histoire de votre marque à travers des images

Haute confidentialité et sécurité
Racontez l'histoire de votre marque à travers des images