Rack Equipments
Expected delivery 3 to 7 business days (exceptions applied)
Tripp Lite
Tripp Lite by Eaton PDUMNV30HV2LX 42 prises PDU - Surveillée - NEMA L6-
Tripp Lite by Eaton PDUMNV30HV2LX 42 prises PDU - Surveillée - NEMA L6-
Prix habituel
$974.84 CAD
Prix habituel
$1,121.07 CAD
Prix promotionnel
$974.84 CAD
Prix unitaire
/
par
Frais d'expédition calculés à l'étape de paiement.
Unité de distribution d'alimentation Tripp Lite by Eaton PDUMNV30HV2LX 42 prises - Surveillée - NEMA L6-30P - 6 x IEC 60320 C19, 36 x IEC 60320 C13 - 230 V CA - 0 U - Verticale - Montable en rack VPN : PDUMNV30HV2LX SKU : RSC526370 CUP :
- Un appareil équipé de sorties multiples pour la distribution de l'énergie électrique
- Le PDU est fiable pour les solutions de protection et de gestion de l'alimentation
- Surveillez à distance la tension monophasée ou triphasée, la fréquence et même les niveaux de charge avec des PDU surveillés
Bloc de texte
Impossible de charger la disponibilité du service de retrait
Remise sur volume disponible - Demandez un devis.
Afficher tous les détails









Recently Viewed
Tripp Lite by Eaton PDUMNV30HV2LX 42 prises PDU - Surveillée - NEMA L6-
Résumé des informations sur le produit

À propos du produit
The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.
The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
- A device fitted with multiple outputs for the distribution of electric power
- PDU is reliable for power protection and management solutions
- Remotely monitor single-or-three phase voltage, frequency even load levels with monitored PDUs
Spécifications techniques
Management | |
Management | Protocols:
|
Miscellaneous | |
Package Contents |
|
Country of Origin | Taiwan |
Environmentally Friendly | Yes |
TAA Compliant | Yes |
Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Power Description | |
Input Voltage | 230 V AC |
Output Voltage | 240 V AC |
200 V AC | |
208 V AC | |
Input Current | 30 A |
Power Rating (Watt) | 5.80 kW |
General Information | |
Product Type | PDU |
Manufacturer Part Number | PDUMNV30HV2LX |
Manufacturer Website Address | http://www.eaton.com/EatonCom/Markets/NorthAmerica |
Manufacturer | Eaton Corporation |
Product Model | PDUMNV30HV2LX |
Product Name | PDUMNV30HV2LX 42-Outlet PDU |
Brand Name | Tripp Lite by Eaton |
Physical Characteristics | |
Weight (Approximate) | 15 lb (6803.89 g) |
Mount Type | Rack-mountable |
Rack Height | 0U |
Height | 70" (1778 mm) |
Width | 2.20" (55.88 mm) |
Depth | 2.65" (67.31 mm) |
Mounting Orientation | Vertical |
Technical Information | |
Plug/Connector Type | NEMA L6-30P |
Phase | Single Phase |
Receptacle Type | IEC 60320 C19 |
IEC 60320 C13 | |
PDU Type | Monitored |
Receptacle Detail | 36 x IEC 60320 C13 |
6 x IEC 60320 C19 |
Comparaison de produits
Garantie du produit
Garantie standard du fabricant, le cas échéant
Politique de retour
Garantie de prix
!00% nous sommes toujours en dessous du prix du marché.
Explorez les collections de marque
Nos services
1
/
de
5

Devenez notre partenaire
Racontez l'histoire de votre marque à travers des images

Éthique et intégrité des affaires élevées
Racontez l'histoire de votre marque à travers des images

Cohérence et performance ciblée
Racontez l'histoire de votre marque à travers des images

Vision partagée et succès partagé
Racontez l'histoire de votre marque à travers des images

Haute confidentialité et sécurité
Racontez l'histoire de votre marque à travers des images