Passer aux informations produits
1 de 12

Power equipment UPS

Expected delivery 3 to 7 business days (exceptions applied)

Tripp Lite

Tripp Lite par Eaton SmartOnline SU3000RTXLCD2UTAA 3000 VA Rack/tour UP

Tripp Lite par Eaton SmartOnline SU3000RTXLCD2UTAA 3000 VA Rack/tour UP

Prix habituel $4,240.96 CAD
Prix habituel $4,749.87 CAD Prix promotionnel $4,240.96 CAD
-10% OFF Épuisé
Frais d'expédition calculés à l'étape de paiement.
Onduleur Tripp Lite par Eaton SmartOnline SU3000RTXLCD2UTAA 3 000 VA pour rack/tour - Rack/tour 2U - Recharge en 3 heures - Autonomie en veille de 4,80 minutes - Entrée 100 V CA, 110 V CA, 120 V CA - Sortie 100 V CA, 110 V CA, 115 V CA, 120 V CA, 127 V CA - Monophasé - Onde sinusoïdale pure - Port série - USB - Écran LCD - 6 prises NEMA 5-20R, 1 prise NEMA L5-30R - Contact sec, DB-9 RS-232, surveillance à distance SNMP/HTTP

VPN : SU3000RTXLCD2UTAA SKU : RSC972172 UPC : 786689875787

  • Capacité de charge de 3 kVA - fonctionne sans interruption en cas de panne de courant
  • Capacité de charge de 2,70 kW - alimentation de secours pour vos précieux appareils électroniques
  • Prévenez la perte de données critiques en restant alimenté pendant une panne de courant avec une capacité de charge allant jusqu'à 2,70 kW

Bloc de texte

Remise sur volume disponible - Demandez un devis.

Afficher tous les détails

Recently Viewed

Tripp Lite par Eaton SmartOnline SU3000RTXLCD2UTAA 3000 VA Rack/tour UP

Résumé des informations sur le produit

Tripp Lite par Eaton SmartOnline SU3000RTXLCD2UTAA 3000 VA Rack/tour UP

À propos du produit

3kVA 2.7kW 120V Battery Backup Protects Equipment Against Damage, Downtime and Data Loss

This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU3000RTXLCD2UTAA provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in the case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP72RT2UTAA, sold separately).

Optional Network Management Card Allows 24/7 Remote Access

The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.Note: The SU3000RTXLCD2UTAA is not compatible with WEBCARDLX.

NEMA Outlets Protect Your Connected Components

One L5-30R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split evenly into two switchable load banks that let you reboot select components or shed non-critical loads in order to extend runtime for critical loads during an outage.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better

This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The two-line front-panel LCD features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery or bypass mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

  • 3 kVA load capacity - work without any interruption during power outages
  • 2.70 kW load capacity - backup power for your valuable electronics
  • Prevent critical data loss by staying powered during a blackout with up to 2.70 kW load capacity
  • 3 kVA load capacity provides sufficient backup during power failures
  • Keep your sensitive devices powered with a backup of up to 4.80 minute at full load
  • Up to 4.80 minute runtime on full load to preserve critical data from power shortage interruptions

Spécifications techniques

Controls/Indicators
Status Indicators

LCD Display:

  • Site Power Status and Operating Data
  • Plus Configuration of Voltage
  • Frequency
  • Operating Mode
  • Alarm Function

LED Indicators:

  • 4 Status-indicating LEDs
Display & Graphics
DisplayLCD
Interfaces/Ports
USBYes
Number of USB Ports1
Serial PortYes
EPO PortYes
Environmental Conditions
Sound Emission47 dB
Thermal Dissipation1462 BTU/h
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature104°F (40°C)
Maximum Operating Elevation10000 ft (3048000 mm)
Miscellaneous
Package Contents
  • SmartOnline SU3000RTXLCD2UTAA 3000VA Rack/tower UPS
  • USB Cable
  • DB9 Cable
  • Rack-mounting Hardware
  • Tower Support Stands
  • Safety Instructions
  • Quick Start Guide
Certifications & Standards
  • UL 1778
  • cTUVus
  • FCC
TAA CompliantYes
Energy StarYes
Environmental ComplianceRegistration, Evaluation, Authorization and Restriction of Chemicals (REACH)
Restriction of Hazardous Substances (RoHS)
Physical Characteristics
Weight (Approximate)63.06 lb (28603.53 g)
Form FactorRack/Tower
Rack Height2U
Height3.41" (86.61 mm)
Width17.33" (440.18 mm)
Depth23.82" (605.03 mm)
Battery Information
Battery ChemistryLead Acid
Hot SwappableYes
Backup/Run Time (Half Load)13.90 Minute
Backup/Run Time (Full Load)4.80 Minute
Battery CharacteristicsValve-regulated
Replaceable BatteryYes
DC System Voltage72 V DC
Typical Battery Recharge Time3 Hour
General Information
Product TypeDouble Conversion Online UPS
Manufacturer Part NumberSU3000RTXLCD2UTAA
Manufacturer Website Addresshttp://www.eaton.com/EatonCom/Markets/NorthAmerica
ManufacturerEaton Corporation
Product ModelSU3000RTXLCD2UTAA
Product NameSmartOnline SU3000RTXLCD2UTAA 3000VA Rack/tower UPS
Product LineSmartOnline
Brand NameTripp Lite by Eaton
Management
Network ManagementDB-9 RS-232
SNMP/HTTP Remote Monitoring
Dry Contact
AlarmRemote Shutdown
Power Failure
Overload
Low Battery
UPS Fault
UPS StartUp
Power Description
Input Voltage110 V AC
120 V AC
100 V AC
Output Voltage100 V AC
127 V AC
120 V AC
115 V AC
110 V AC
Input Current24 A
Surge Energy Rating190 J
Waveform TypePure Sine Wave
Output Frequency50 Hz
60 Hz
Load Capacity (VA)3 kVA
Load Capacity (Watt)2.70 kW
Input Power Factor0.99
Output Power Factor0.9
Technical Information
Application/UsageNon-critical Device
Network Device
Network
Mission Critical Equipment
Military
Industrial Equipment
IT
Education
Government
Healthcare
IT Equipment
FeaturesAudible Alarm
Cold Start Function
Surge SuppressionYes
Plug/Connector TypeNEMA L5-30P
Cord Length8 ft (2.44 m)
PhaseSingle Phase
Receptacle TypeNEMA L5-30R
NEMA 5-20R
EMI/RFI Noise FilterYes
Energy SavingGreen Energy-Saving
Transfer Time0 ns
Receptacle Detail6 x NEMA 5-20R
1 x NEMA L5-30R
Efficiency Detail91.6% (AC Mode)
96.8% (Eco Mode)

Comparaison de produits

Garantie du produit

Garantie standard du fabricant, le cas échéant

Politique de retour

Garantie de prix

!00% nous sommes toujours en dessous du prix du marché.

Explorez les collections de marque

Nos services

1 de 5
  • Colonne

    Concevoir et construire des espaces de travail, des salles de conférence et des salles de réunion
    Voir plus 
  • Colonne

    Service informatique géré, services d'assistance, serveurs et réseaux
    Voir plus 
  • Colonne

    Évaluation, acquisition et personnalisation des appareils de nouvelle génération
    Voir plus 
  • Colonne

    Continuité des activités, sécurité, sauvegarde et reprise après sinistre
    Voir plus 
  • Colonne

    Structure du cloud, migration, optimisation et sécurité
    Voir plus 
  • Colonne

    Numérisation, conservation des données, automatisation, applications de développement