Skip to product information
1 of 1

Electrical Products

Expected delivery 3 to 7 business days (exceptions applied)

Dataprobe

Dataprobe iBoot-PDU8A-N20 Switched PDU 8 Outlet 20A (IBOOT-PDU8A-N20)

Dataprobe iBoot-PDU8A-N20 Switched PDU 8 Outlet 20A (IBOOT-PDU8A-N20)

Regular price $940.99 CAD
Regular price $1,053.99 CAD Sale price $940.99 CAD
-10% OFF Ask for quote
Shipping calculated at checkout.

Dataprobe iBoot-PDU8A-N20 Switched PDU 8 Outlet 20A (IBOOT-PDU8A-N20)

VPN:IBOOT-PDU8A-N20      SKU:AT901415      UPC:700220864580

Volume discount available - Ask for quote..

View full details

Recently Viewed

Dataprobe iBoot-PDU8A-N20 Switched PDU 8 Outlet 20A (IBOOT-PDU8A-N20)

Product information summary

Dataprobe iBoot-PDU8A-N20 Switched PDU 8 Outlet 20A (IBOOT-PDU8A-N20)

About the product

Dataprobe iBoot-PDU8A-N15 Switched PDU 8 Outlet 15A

  • Independently Controllable Outlets
    • The iBoot-PDU series is designed to provide power distribution and remote power control. Each iBoot-PDU allows four or eight outlets to be independently switched on and off for reboot, energy management, and security. The iBoot-PDU has many features to make the management of power distribution simple and cost-effective
  • Web Browser Control
    • A simple web browser interface is easy to use and provides complete status information and control of the outlets, and groups.
  • Integrated 1Gig Ethernet Switch
    • Simplify network wiring and reduce home runs to the router. This two-port passive switch makes it easy to add remote power management to existing installations.
  • Telnet/Serial CLI Control
    • Telnet and serial access use the same Command Line Interface (CLI) structure and syntax to completely configure the iBoot-PDU or multiple iBoot-PDUs in a cluster configuration.
  • Multiple Users
    • Multiple users can be assigned administrator or user-only rights, plus access to specific outlets and groups. Users only see the outlets and groups they are assigned to.
  • Grouping of Outlets for Simultaneous Management
    • Multiple outlets, across multiple iBoot-PDUs in clustered configurations can be linked together in named groups and managed together. This allows, for example, power cycling all devices of a certain type together.
  • Multiple iBoot-PDU Cluster Configuration
    • Additional iBoot-PDUs can be managed from a single unit. One master iBoot-PDU provides communication to the users and continuously receives status information from the rest of the iBoot-PDUs in the cluster. Groups can be created across multiple PDUs and controlled simultaneously.
  • Automation
    • The iBoot-PDU can monitor voltage, current, and temperature to provide an automatic response to the physical environment. AutoPing testing monitors network elements. Program complex sequences of outlet actions and notifications to respond instantly to out-of-normal situations. Temperature monitoring requires an add-on probe.
  • Real-Time Event Control
    • Set automatic power actions based on your schedule. Restart systems every day to reduce memory bloat. Power up resources only when needed for energy management, lifecycle extension, or security.
  • Landline Modem Option
    • The add-on landline modem supports data calls from terminal devices using the CLI, and direct dial from a tone telephone for simple on/off control when more sophisticated means are not available. Voice modem also allows phone dial tone control with voice response (Basic functions only)
  • Network Management
    • Setup and Control functions can be linked to any SNMP v2c compatible manager. The iBoot-PDU MIB is downloadable from the website. Reports to Syslog server.
  • Intuitive Dashboard
    • The dashboard provides a clear status indication of each outlet, current draw across all inputs, and alarm trigger status Multiple PDUs can be managed from a single web page. Select one or more outlets and reboot or switch power.
  • Powerful Automation
    • Monitor critical parameters and take corrective action immediately. Build complex notification and reporting for environmental, power, and network faults. Set trigger points and create sequences of responses to keep your network up and running.
  • Advanced AutoPing
    • The sophisticated AutoPing feature detects downtime in critical systems and automatically reboots whenever needed.
  • Global-View
    • Multiple PDUs can be managed from a single dashboard. The Global-View is a compressed presentation for controling all the PDUs from a single page.

 

Dataprobe iBoot-PDU8A-N15 Switched PDU 8 Specifications

  • Physical
    • Height: 1U 1.75 in (4.5 cm)
    • Width: 11.0 in (27.94 cm)
    • Depth: 6.00 in (15.25 cm)
    • Weight: 4.5 lbs (2 kg)
    • Temperature
      • Operating: 0 to 65o C
      • Storage: -10 to 85o C
      • Relative Humidity: 0 to 95% Non-Condensing
      • Altitude: 2000m Operating
  • AC Input
    • 115 VAC
    • 15 AMP Models: NEMA 5-15 Line cord 115VAC
    • 20 AMP Models: NEMA 5-20 Line cord 115VAC
  • Network
    • Single or Dual (S Models) 1G Ethernet
    • Web, Telnet, SNMP, SMTP
    • Port Assignable for Web and Telnet.
    • SSL Security on Web control
  • USB Ports
    • 4 x USB A ports for accessories, modem, temperature probe, etc.
    • 1 x USB B port for serial port and external battery
  • Temperature Module Option
    • USB Dual Temperature Sensors. Sensor 2 on 1m cable.
  • Landline Modem Option
    • 56Kbps V.92 Global Compliance, Data or Tone Dial (DTMF) control
  • Switched Outlet
    • 4 or 8 NEMA 5-15 Receptacle
    • 12 Amps Max per Receptacle
    • -N15 Models: 15 Amps Max Total per Line cord
    • -N20 Models, 20 Amps Max Total per Line cord
  • Compliance - Safety
    • Complies with UL62638-1, 2nd Edition, 2014-12-01 (US),
    • IEC62638-1:2014 EN 62368-1:2014 + A11:2017 
    • Complies with CAN/CSA C22.2 No. 62638-1-14, 2nd Edition, 2014-12-01 (Canada) 
  • Compliance-Emissions
    • ANSI C63.4:2014 & 47 CFR Part 15, Subpart B, Class B
    • ICES-003:2016 Issue 6, Class BFCC Part 15 Class B
  • Compliance-Environmental
    • RoHS 3 Directive (EU) 2015/863Compliant 
    • WEEE Compliant
    • Rated Pollution Degree 2 (PD 2) for use in business/laboratory environments with only Non-Conductive pollution present 

 

    Technical Specifications

    Dataprobe iBoot-PDU8A-N15 Switched PDU 8 Outlet 15A

    • Independently Controllable Outlets
      • The iBoot-PDU series is designed to provide power distribution and remote power control. Each iBoot-PDU allows four or eight outlets to be independently switched on and off for reboot, energy management, and security. The iBoot-PDU has many features to make the management of power distribution simple and cost-effective
    • Web Browser Control
      • A simple web browser interface is easy to use and provides complete status information and control of the outlets, and groups.
    • Integrated 1Gig Ethernet Switch
      • Simplify network wiring and reduce home runs to the router. This two-port passive switch makes it easy to add remote power management to existing installations.
    • Telnet/Serial CLI Control
      • Telnet and serial access use the same Command Line Interface (CLI) structure and syntax to completely configure the iBoot-PDU or multiple iBoot-PDUs in a cluster configuration.
    • Multiple Users
      • Multiple users can be assigned administrator or user-only rights, plus access to specific outlets and groups. Users only see the outlets and groups they are assigned to.
    • Grouping of Outlets for Simultaneous Management
      • Multiple outlets, across multiple iBoot-PDUs in clustered configurations can be linked together in named groups and managed together. This allows, for example, power cycling all devices of a certain type together.
    • Multiple iBoot-PDU Cluster Configuration
      • Additional iBoot-PDUs can be managed from a single unit. One master iBoot-PDU provides communication to the users and continuously receives status information from the rest of the iBoot-PDUs in the cluster. Groups can be created across multiple PDUs and controlled simultaneously.
    • Automation
      • The iBoot-PDU can monitor voltage, current, and temperature to provide an automatic response to the physical environment. AutoPing testing monitors network elements. Program complex sequences of outlet actions and notifications to respond instantly to out-of-normal situations. Temperature monitoring requires an add-on probe.
    • Real-Time Event Control
      • Set automatic power actions based on your schedule. Restart systems every day to reduce memory bloat. Power up resources only when needed for energy management, lifecycle extension, or security.
    • Landline Modem Option
      • The add-on landline modem supports data calls from terminal devices using the CLI, and direct dial from a tone telephone for simple on/off control when more sophisticated means are not available. Voice modem also allows phone dial tone control with voice response (Basic functions only)
    • Network Management
      • Setup and Control functions can be linked to any SNMP v2c compatible manager. The iBoot-PDU MIB is downloadable from the website. Reports to Syslog server.
    • Intuitive Dashboard
      • The dashboard provides a clear status indication of each outlet, current draw across all inputs, and alarm trigger status Multiple PDUs can be managed from a single web page. Select one or more outlets and reboot or switch power.
    • Powerful Automation
      • Monitor critical parameters and take corrective action immediately. Build complex notification and reporting for environmental, power, and network faults. Set trigger points and create sequences of responses to keep your network up and running.
    • Advanced AutoPing
      • The sophisticated AutoPing feature detects downtime in critical systems and automatically reboots whenever needed.
    • Global-View
      • Multiple PDUs can be managed from a single dashboard. The Global-View is a compressed presentation for controling all the PDUs from a single page.

     

    Dataprobe iBoot-PDU8A-N15 Switched PDU 8 Specifications

    • Physical
      • Height: 1U 1.75 in (4.5 cm)
      • Width: 11.0 in (27.94 cm)
      • Depth: 6.00 in (15.25 cm)
      • Weight: 4.5 lbs (2 kg)
      • Temperature
        • Operating: 0 to 65o C
        • Storage: -10 to 85o C
        • Relative Humidity: 0 to 95% Non-Condensing
        • Altitude: 2000m Operating
    • AC Input
      • 115 VAC
      • 15 AMP Models: NEMA 5-15 Line cord 115VAC
      • 20 AMP Models: NEMA 5-20 Line cord 115VAC
    • Network
      • Single or Dual (S Models) 1G Ethernet
      • Web, Telnet, SNMP, SMTP
      • Port Assignable for Web and Telnet.
      • SSL Security on Web control
    • USB Ports
      • 4 x USB A ports for accessories, modem, temperature probe, etc.
      • 1 x USB B port for serial port and external battery
    • Temperature Module Option
      • USB Dual Temperature Sensors. Sensor 2 on 1m cable.
    • Landline Modem Option
      • 56Kbps V.92 Global Compliance, Data or Tone Dial (DTMF) control
    • Switched Outlet
      • 4 or 8 NEMA 5-15 Receptacle
      • 12 Amps Max per Receptacle
      • -N15 Models: 15 Amps Max Total per Line cord
      • -N20 Models, 20 Amps Max Total per Line cord
    • Compliance - Safety
      • Complies with UL62638-1, 2nd Edition, 2014-12-01 (US),
      • IEC62638-1:2014 EN 62368-1:2014 + A11:2017 
      • Complies with CAN/CSA C22.2 No. 62638-1-14, 2nd Edition, 2014-12-01 (Canada) 
    • Compliance-Emissions
      • ANSI C63.4:2014 & 47 CFR Part 15, Subpart B, Class B
      • ICES-003:2016 Issue 6, Class BFCC Part 15 Class B
    • Compliance-Environmental
      • RoHS 3 Directive (EU) 2015/863Compliant 
      • WEEE Compliant
      • Rated Pollution Degree 2 (PD 2) for use in business/laboratory environments with only Non-Conductive pollution present 

     

      Product compare

      Product warranty

      Standard manufacturer warranty as applicable

      Return policy

      15 days return in original condition.

      Price guarantee

      !00% we are always lower than market price.

      Explore branded collections

      Our services

      1 of 5
      • Design and build workplace, conference rooms & boardroom
        See more 
      • Managed IT service, help desks, servers, & networking
        See more 
      • Next generation devices assess, procure, customization
        See more 
      • Business continuity, security, backup & disaster recovery
        See more 
      • Cloud structure, migration, optimization and security
        See more 
      • Digitization, data retention, automation, Dev apps
        See more 

      Contact us