The Honeywell N100 FocusPRO Non-Programmable Thermostat with 3 Heat and 2 Cool is a simple, battery-powered/low-voltage thermostat with an LED display designed for multi-stage heat & cool systems: including up to 3H/2C Heat Pump systems, up to 2H/2C conventional systems; gas, oil, electric radiators; steam/radiant hot water systems, and heat pumps with Auxiliary Heat.
Includes a built-in low-battery alert and an optional air filter replacement reminder for optimizing HVAC equipment uptime.
Powered by 24V low-voltage power supply or 2 AA batteries (included).
Includes 5-year manufacturer’s warranty. Package includes thermostat, UWP wall plate, decorative cover plate with J-box adaptor, mounting hardware, AA batteries, and user manual.
Thermostat UWP mounting plate includes mounting hardware. Use optional cover plate with J-box adapter (also included with thermostat) to cover marks from the previous thermostat or mount to a J- box.
Also works with Honeywell Outdoor Temperature sensors (sold separately).
TH1320U4002 Specs and Features
- Temperature Setpoint Range:
- Heating: 0 °C to 32 °C (32 °F to 90 °F)
- Cooling: 10 °C to 37 °C (50 °F to 99 °F)
- Temperature Sensor Accuracy: ± 0.5 °C at 21.0 °C (1 °F at 70 °F)
- Display Info: Mode, Current Temperature, Set Temperature, Status Display, Fan
- Custom Options:
- Fan lockout after cool call option
- Heat and cool range settings
- Upstage timer for backup heat. Change filter reminder
- Custom display settings
- Alerts and Reminders: Battery Replacement, Heat Pump Failure, Filter Change
- Power method: Hardwired or Battery Operated; 24 volts to RC and C or 2 AA alkaline batteries (included)
- Terminal Designations: R, RC, C, W, O/B, W2-AUX, E, Y, Y2, G, and L/A
- Electrical Ratings:
- W Heating: 20-30 VAC @ 0.02-1.0 A / 750 MV
- W2 (Aux) Heating: 20-30 VAC @ 0.02-1.0 A
- E Emergency Heat: 20-30 VAC @ 0.02-0.5 A
- Y Compressor Stage 1: 20-30 VAC @ 0.02-1.0 A
- Y2 Compressor Stage 2: 20-30 VAC @ 0.02-1.0 A
- G Fan: 20-30 VAC @ 0.02-0.5 A
- O/B Changeover: 20-30 VAC @ 0.02-0.5 A
- L/A Input: 20-30 VAC @ 0.02-0.5 A
- Ambient Operating Temperature: 0 °C to 38.9 °C (32 °F to 102 °F)
- Relative Operating Humidity: 5% to 90% (non condensing)
- Dimensions: 5-1/8” W x 3-7/16” H x 1-3/16” D (130 mm W x 87 mm H x 29.5 mm D)
- 5 Year Manufacturer’s Warranty
Technical Specifications
The Honeywell N100 FocusPRO Non-Programmable Thermostat with 3 Heat and 2 Cool is a simple, battery-powered/low-voltage thermostat with an LED display designed for multi-stage heat & cool systems: including up to 3H/2C Heat Pump systems, up to 2H/2C conventional systems; gas, oil, electric radiators; steam/radiant hot water systems, and heat pumps with Auxiliary Heat.
Includes a built-in low-battery alert and an optional air filter replacement reminder for optimizing HVAC equipment uptime.
Powered by 24V low-voltage power supply or 2 AA batteries (included).
Includes 5-year manufacturer’s warranty. Package includes thermostat, UWP wall plate, decorative cover plate with J-box adaptor, mounting hardware, AA batteries, and user manual.
Thermostat UWP mounting plate includes mounting hardware. Use optional cover plate with J-box adapter (also included with thermostat) to cover marks from the previous thermostat or mount to a J- box.
Also works with Honeywell Outdoor Temperature sensors (sold separately).
TH1320U4002 Specs and Features
- Temperature Setpoint Range:
- Heating: 0 °C to 32 °C (32 °F to 90 °F)
- Cooling: 10 °C to 37 °C (50 °F to 99 °F)
- Temperature Sensor Accuracy: ± 0.5 °C at 21.0 °C (1 °F at 70 °F)
- Display Info: Mode, Current Temperature, Set Temperature, Status Display, Fan
- Custom Options:
- Fan lockout after cool call option
- Heat and cool range settings
- Upstage timer for backup heat. Change filter reminder
- Custom display settings
- Alerts and Reminders: Battery Replacement, Heat Pump Failure, Filter Change
- Power method: Hardwired or Battery Operated; 24 volts to RC and C or 2 AA alkaline batteries (included)
- Terminal Designations: R, RC, C, W, O/B, W2-AUX, E, Y, Y2, G, and L/A
- Electrical Ratings:
- W Heating: 20-30 VAC @ 0.02-1.0 A / 750 MV
- W2 (Aux) Heating: 20-30 VAC @ 0.02-1.0 A
- E Emergency Heat: 20-30 VAC @ 0.02-0.5 A
- Y Compressor Stage 1: 20-30 VAC @ 0.02-1.0 A
- Y2 Compressor Stage 2: 20-30 VAC @ 0.02-1.0 A
- G Fan: 20-30 VAC @ 0.02-0.5 A
- O/B Changeover: 20-30 VAC @ 0.02-0.5 A
- L/A Input: 20-30 VAC @ 0.02-0.5 A
- Ambient Operating Temperature: 0 °C to 38.9 °C (32 °F to 102 °F)
- Relative Operating Humidity: 5% to 90% (non condensing)
- Dimensions: 5-1/8” W x 3-7/16” H x 1-3/16” D (130 mm W x 87 mm H x 29.5 mm D)
- 5 Year Manufacturer’s Warranty
Product compare
Product warranty
Standard manufacturer warranty as applicable
Return policy
15 days return in original condition.
Price guarantee
!00% we are always lower than market price.
Explore branded collections
Our services

Partner with us

High business ethics and integrity

Consistence and focused performance

Shared vision and shared success

High confidentiality and security
-
See more
Design and build workplace, conference rooms & boardroom
-
See more
Managed IT service, help desks, servers, & networking
-
See more
Next generation devices assess, procure, customization
-
See more
Business continuity, security, backup & disaster recovery
-
See more
Cloud structure, migration, optimization and security
-
See more
Digitization, data retention, automation, Dev apps