Advantech
Advantech B+B SmartWorx RS-232 a RS
Advantech B+B SmartWorx RS-232 a RS
- Con el adaptador de transferencia de datos, transfiera datos fácilmente a alta velocidad
- Adaptador serial rápido y confiable
No se pudo cargar la disponibilidad de retiro
Descuento por volumen disponible: solicite cotización.
Ver todos los detalles

Recently Viewed
Advantech B+B SmartWorx RS-232 a RS
Resumen de información del producto
Acerca del producto
Model BB-485PTBR converts unbalanced RS-232 signals to balanced, full or half-duplex RS-485 signals. RS-485 is an enhanced version of the RS-422 Standard allowing multiple drivers and receivers on a two-wire system. The RS-232 port has a female DB9 connector with pins 2(RD), 3(TD), and 5(SG) supported. Pins 7(RTS) and 8(CTS) are tied together. Also pins 6(DSR), 1(CD), and 4(DTR) are tied together, but not passed through the converter. The RS-485 port has an 8-position pluggable terminal block connector.
Baud Rate
Model BB-485PTBR supports baud rates from 300 bps to 115.2 Kbps. In order to change the baud rate, a resistor and possibly a capacitor must be changed. By looking up the selected baud rate on Table 1 the resistor and capacitor value can be determined. Remove R3 and C7 from the printed circuit board. Place new components in the R2 and C6 locations.
Biasing Resistors
The biasing resistors R5 and R7 can also be altered. Model BB-485PTBR comes standard with 4.7K biasing resistors. To change the value of biasing resistors, remove R5 and R7 and replace with new value in locations R4 and R6.
Termination Resistor
The termination resistor is located at R8. A termination resistor can be placed in the R8 location and a jumper wire placed from the terminal location to RD(B). B+B SmartWorx recommends a 100-120 Ohm resistor for termination.
Constant Receiver Enable
The BB-485PTBR is factory-set with the receiver disabled during transmission. It can be set for constant receiver enable. When R9 is removed, the receiver is in constant receive mode (four-wire). When R9 is in the circuit it is in half-duplex mode (two-wire).
Data Line Polarity
The polarity of the two RS-485 lines must be correct. With no data being sent, the RS-232 line should be negative and the RS-485 "A" terminal should be negative with respect to the "B" terminal. If your equipment uses a "+" and "-" naming scheme, in most cases, the "A" line will be connected to the "-" and the "B" line will be connected to the "+".
- With data transfer adapter easily transfer data with high speed
- Fast and reliable Serial adapter
Especificaciones técnicas
| Miscellaneous | |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Waste Electrical and Electronic Equipment Directive (WEEE) | |
| Physical Characteristics | |
| Material Details | Plastic - Enclosure |
| Weight (Approximate) | 30 g |
| Product Material | Plastic |
| Technical Information | |
| Connector Type on First End | DB-9 RS-232 Serial - Female |
| Connector Type on Second End | Terminal Block RS-485 Serial |
| Adapter Type | Serial |
| Connector on First End Details | 1 x DB-9 RS-232 Serial - Female |
| Connector on Second End Details | 1 x Terminal Block RS-485 Serial |
| Connector Gender on First End | Female |
| General Information | |
| Product Type | Data Transfer Adapter |
| Manufacturer Part Number | 485PTBR |
| Manufacturer Website Address | http://www.advantech.com |
| Manufacturer | Advantech Co., Ltd |
| Product Model | BB-485PTBR |
| Product Name | RS-232 to RS-485 Converter with Pluggable Terminal Block |
| Brand Name | B+B SmartWorx |
Comparación de productos
Garantía del producto
Garantía estándar del fabricante según corresponda
Política de devoluciones
Garantía de precio
!00% siempre estamos por debajo del precio del mercado.
Explora colecciones de marca
Nuestros servicios
Asociate con nosotros
Alta ética e integridad empresarial
Consistencia y rendimiento enfocado
Visión compartida y éxito compartido
Alta confidencialidad y seguridad
-
Ver másDiseño y construcción de lugares de trabajo, salas de conferencias y salas de juntas.
-
Ver másServicio de TI administrado, mesas de ayuda, servidores y redes
-
Ver másDispositivos de próxima generación: evaluación, adquisición y personalización
-
Ver másContinuidad de negocio, seguridad, copias de seguridad y recuperación ante desastres
-
Ver másEstructura de la nube, migración, optimización y seguridad
-
Ver másDigitalización, retención de datos, automatización, aplicaciones de desarrollo