Ir directamente a la información del producto
1 de 3

Rack Equipments

Expected delivery 3 to 7 business days (exceptions applied)

Lenovo

PDU trifásicas conmutadas y monitoreadas de 1U de Lenovo - Monitoreo de tomacorrientes conmutados

PDU trifásicas conmutadas y monitoreadas de 1U de Lenovo - Monitoreo de tomacorrientes conmutados

Precio habitual $5,374.99 CAD
Precio habitual $6,019.99 CAD Precio de oferta $5,374.99 CAD
-10% OFF Agotado
Los gastos de envío se calculan en la pantalla de pago.
PDU trifásicas conmutadas y monitoreadas Lenovo 1U - Salida conmutada monitoreada - 12 x Combinación C13/C19 - 230 V CA - 1U - Montaje en rack - Rack

VPN:4PU7A77469 SKU:RSC944701 UPC:

  • El formato 1U permite implementaciones de alta corriente en una PDU compacta. Puede instalarse verticalmente en el compartimento lateral de un rack o horizontalmente en la parte trasera de un espacio de rack (unidad de rack 1U).
  • Las tomas de corriente combinadas C13/C19 se adaptan a los requisitos de energía del rack en constante cambio con la flexibilidad de conectar enchufes C14 o C20 en la misma toma.
  • PDU totalmente monitoreada y administrada que incluye medición de corriente residual tipo B

Bloque de texto

Descuento por volumen disponible: solicite cotización.

Ver todos los detalles

Recently Viewed

PDU trifásicas conmutadas y monitoreadas de 1U de Lenovo - Monitoreo de tomacorrientes conmutados

Resumen de información del producto

PDU trifásicas conmutadas y monitoreadas de 1U de Lenovo - Monitoreo de tomacorrientes conmutados

Acerca del producto

A power distribution unit (PDU) is a highly reliable, multiple outlet power strip designed to consolidate line cords within the rack and distribute conditioned power from an uninterruptible power supply (UPS) or utility power to servers and other IT equipment. The PDU efficiently distributes power within the rack and provides fault-tolerant power redundancy for high availability requirements.

There are three types of PDUs available from Lenovo: basic, monitored, and switched & monitored. The PDUs covered in this document are of the switched & monitored type.
  • Basic PDUs: The simplest and most cost-effective power distribution. Available with various outlet configurations and line cord options to support different systems and load requirements.
  • Monitored PDUs: provides the same benefits as a Basic PDU, but adds additional advanced PDU power monitoring down to the load group. This enables businesses to have a cross-platform racklevel power and thermal view for trending analysis to improve power management
  • Switched & monitored PDUs: These are advanced power management solutions, providing power monitoring at the outlet level, with increased accuracy at low amperages, for more precise views of power consumption down to the individual server level instead of at the consolidated load group. These PDUs also offer management via a web-based interface which includes individual outlet switching (on/off). Outlet switching allows for remote power sequencing and helps prevent unintended PDU overloading.
  • 1U form factor allows for high-current deployments in a compact PDU. Can be installed vertically in the side pocket of a rack cabinet or horizontally at the rear of a rack space (1U rack unit)
  • Combination C13/C19 outlets (receptacles) accommodate ever-changing rack power requirements with the flexibility to connect C14 or C20 plugs in the same outlet.
  • Fully monitored and managed PDU including Residual Current Metering Type B
  • Interchangeable Monitoring Device (IMD) is hot-swappable and includes ports for serial communication, environmental monitoring, and dual Gigabit Ethernet ports to simplify management of multiple PDUs with fault-tolerant daisy chaining or IP aggregation capabilities. One of these ports can be used to connect the IMD to an existing network or both ports can be used at the same time to connect one IMD to another in a daisy-chain configuration.
  • Easily identify circuits with color-coded P-Lock tabs, streamlining circuit and phase balancing with alternating outlets.
  • The use of P-Lock tabs on the outlets reduce the chance of accidental removal of a power cord from the PDU (P-Lock compatible cord sets required for locking feature)
  • Comprehensive power management and flexible configuration
  • Supported protocols: DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
  • Detailed data-logging for statistical analysis and diagnostics
  • Easy-to-use interface to display input and output status

Especificaciones técnicas

Management
Management
  • DHCP
  • HTTP
  • HTTPS
  • IPv4
  • IPv6
  • LDAP
  • NTP
  • RADIUS
  • RSTP
  • SSH
  • SMTP
  • SNMP (v1/v2c/v3)
  • Syslog
  • TACACS+
Remote Outlet SwitchingYes
Miscellaneous
Package Contents
  • 1U Switched & Monitored 3-Phase PDUs
  • Power Cord
  • Mounting Rails
  • Rack Mounting Hardware Kit
  • M6 Cage Nuts
  • Supporting Screws/Nuts
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Power Description
Input Voltage230 V AC
Input Current60 A
Input Voltage Range200 V AC - 240 V AC
Power Rating (Watt)17.20 kW
General Information
Product TypePDU
Manufacturer Part Number4PU7A77469
Manufacturer Website Addresshttp://www.lenovo.com
ManufacturerLenovo Group Limited
Product Name1U Switched & Monitored 3-Phase PDUs
Brand NameLenovo
Technical Information
FeaturesCompact
Protection TypeCircuit Breaker
PhaseThree Phase
Receptacle TypeCombination C13/C19
PDU TypeSwitched Outlet Monitored
Receptacle Detail12 x Combination C13/C19
Physical Characteristics
Weight (Approximate)26.46 lb (12000 g)
Form FactorRack
Mount TypeRack-mountable
Rack Height1U
Height1.70" (43.18 mm)
Width17.50" (444.50 mm)
Depth14" (355.60 mm)

Comparación de productos

Garantía del producto

Garantía estándar del fabricante según corresponda

Política de devoluciones

Garantía de precio

!00% siempre estamos por debajo del precio del mercado.

Explora colecciones de marca

Nuestros servicios

1 de 5
  • Columna

    Diseño y construcción de lugares de trabajo, salas de conferencias y salas de juntas.
    Ver más 
  • Columna

    Servicio de TI administrado, mesas de ayuda, servidores y redes
    Ver más 
  • Columna

    Dispositivos de próxima generación: evaluación, adquisición y personalización
    Ver más 
  • Columna

    Continuidad de negocio, seguridad, copias de seguridad y recuperación ante desastres
    Ver más 
  • Columna

    Estructura de la nube, migración, optimización y seguridad
    Ver más 
  • Columna

    Digitalización, retención de datos, automatización, aplicaciones de desarrollo
    Ver más 

Contáctanos